      Support Home arrow FAQs arrow Can you explain the connections on the FIB2-Serial for RS-232 5-Wire mode? Friday, 18 May 2012      
 
Can you explain the connections on the FIB2-Serial for RS-232 5-Wire mode?

The FIB2-Serial operate in pairs with a fiber link between them. When they are is set to RS-232 5-Wire mode, the pair provides transparent signal and flow control between the two units and can act as DTE or DCE depending on the direction of the data and flow control. The following should give a better idea of the way the link works.


                   +----------+        +----------+
RS-232 data(IN) -->|          |        |          |--> RS-232 data(OUT)
                   |          |        |          |
RS-232 data(out)<--|          |--------|          |<-- RS-232 data(IN)
                   | FIB2     | fiber  | FIB2     |
Flow Ctrl(IN)----->|          |--------|          |--> Flow Ctrl(OUT)
                   |          |        |          |
Flow Ctrl(OUT)<----|          |        |          |<-- Flow Ctrl(IN)
                   +----------+        +----------+


The flow control signals can be of your own choosing. For example, send a RTS signal at a flow control in and on the other side out of the fiber link take the resultant flow control and send to CTS. Using the above scheme, you can provide one hardware flow control signal in each direction.

 
 
Newsflash
The FRM220 is a 20 slot 2RU tall 19" rack mountable platform media converter chassis with redundant power and all hot swappable design. Logon to our support web for more details on how you can demo the web management online.
 
  CTC Union Support Web